Mouse anti Human CD19

Mouse anti Human CD19, Monoclonal, IgG1, Clone: 1G9
Artikelnummer
EXA0191
Verpackungseinheit
100 µg
Hersteller
Exalpha Biologicals Inc

Verfügbarkeit: wird geladen...
Preis wird geladen...
Clone: 1G9.

Background: Identification of human B cells associated approximately with10% of peripheral blood lymphocytes, 95,000 M.W. surface antigen.

Purification Method: Protein A/G Chromatography.

Formulation: Provided as solution in phosphate buffered saline with 0.08% sodium azide.

References: 1. Functional Properties of CD19+ B Lymphocytes Positively Selected from Buffy Coats by Immunomagnetic Separation. Funderud S., Erikstien B., Asheim H.C., Nustad K., Stokke T., Blomhoff H.K., Holte H, Smeland E.B., Eur. J. Immunol. 1990 Ja;20(1):201-6.

2. Thymic B Cells from Myasthenia Gravis Patients are Activated B Cells. Phenotypic and Functional Analysis. Leprince C., CohenKaminsky S., Berrih-Aknin S., Vernet-Der Garabedian B., Treton D., Galanaud P., Richard Y., J. Immunol. 1990 Oct., 145(7):2115-22.

3. Prognostic Significance of CD34 Expression in Childhood B Precursor Acute Lymphocytic Leukemia: A Pediatric Onocology Group Study. Borowitz MJ, Shuster JJ, Civin CI, Carrol AJ, Look AT, Behm FG, Land VJ, Pullen DJ, Crist WM, J. Clin. Onol. 1990 Au;8(8):1389-98.

4. Biphenotypic Acute Leukemia in Adults. Sulak LE, Clare CN, Morale BA, Hansen KL, Montiel MM, Am. J. Clin. Path. 1990 Ju;94(1):54-8.

5. Intersection of the Complement and Immune Systems: A Signal Transduction Complex of the B Lymphocyte Containing Complement Receptor type 2 and CD19. Matsumoto AK, Kopicky-Burd J., Carter Rh, Tuveson DA, Tedder TF, Fearon, DT, J. Exp. Med. 1991 Jan. 173(1):55-64.

6. Immunofluorescence Measurement in a Flow Cytometer using Low-Power Helium Neon Laser Excitation. Shapiro, H.M, Glazer, A.N., Christenson, L., Williams, J.M., and Strom, T. B. Cytometry 4,276, 1983.

7. Comparison of Helium Neon and Dye lasers for Excitation of Allophycocyanin. Loken, M.R., Kiej, J.F. and Kelly, K.,A. Cytometry 8, 96, 1987.

UniProt: P15391.

Caution: This product is intended FOR RESEARCH USE ONLY, and FOR TESTS IN VITRO, not for use in diagnostic or therapeutic procedures involving humans or animals.
Mehr Informationen
Artikelnummer EXA0191
Hersteller Exalpha Biologicals Inc
Hersteller Artikelnummer 0191
Green Labware Nein
Verpackungseinheit 100 µg
Mengeneinheit STK
Reaktivität Human
Klonalität Monoclonal
Methode Flow Cytometry
Isotyp IgG1
Wirt Mouse
Produktinformation (PDF) Download
MSDS (PDF) Download