Endotoxin

Endotoxin

Since the pharmaceutical industry produces injections of many kinds, testing for pyrogens is an absolute necessity. Pyrogens are substances that can cause fever, shock and in extreme cases even the death. Endotoxin is a pyrogen of Gram-negative bacteria. It is found as a natural component in the outer cell membrane and is released by cell lysis. Over 30 different biological activities of endotoxin are known, including macrophage activation, mitogenic activity and induction of interferon and colony-stimulating factors.

For a long time, the "Rabbit Pyrogen Test" was the drug of choice. In the 1970s, the LAL test (Limulus Amebocyte Lysate) was introduced. LAL comes from the amebocytes of the horseshoe crab Limulus polyphemus. Frederick Bang and Jack Levin observed that these amebocytes coagulate in the presence of Gram-negative bacteria. The technology for the endotoxin test was derived from this observation.

Gel Clot LAL assays

The Pyrogent Gel Clot Assay is a qualitative LAL test for endotoxins from Gram-negative bacteria. The assay is performed in glass tubes at 37°C. After one hour of incubation in a water bath or incubation block, the tubes are inverted 180°. If endotoxin contamination is present, a gel-like matrix will form and remain intact when the tube is inverted.

Kinetic Turbidimetric LAL Assays

For a quantitative endotoxin determination, Lonza offers the Kinetic Turbidimetric LAL Assays. This method is performed in a microplate using an incubating absorbance plate reader at the wavelength 340nm and at 37°C. Using special software, the turbidity is monitored over time. Endotoxin-containing samples show a faster increase in OD than non-contaminated samples. Endotoxin concentrations of samples can be determined.

Endpoint chromogenic LAL assays

This method is carried out in tubes or in microplates. After a certain time, the reaction mixture turns yellow and can be measured with a photometer at 405-410 nm. Positive samples give a stronger discoloration, or higher OD value. Using the accompanying standard, sample values can be quantitatively calculated.

Kinetic Chromogenic LAL Assays

Similar to the Endpoint Chromogenic LAL Assay, this method uses an absorbance reading at 405-410 nm. These tests are particularly suitable for the quality control of biological products, e.g. vaccines or antibiotics. The sensitivity range is between 0.005 and 50 EU / mL.

PyroGene Endpoint Fluorogenic LAL Assays

The PyroGene assay is a reliable alternative to traditional endotoxin tests. It relies on the activation of recombinant Factor C, an endotoxin-sensitive protein that initiates the traditional LAL cascade. The measurement is carried out with a fluorescence reader (ex: 380 nm / em: 440 nm) in a microplate. Standards allow quantification of positive samples in the range 0.01-10 EU / mL.

Set Descending Direction

147 items

per page
  1. Tips LAL reag grade 1250µL 10x96 tips
    LAL Reagent GradeTMPipette Tips, 50–1250 µL, <0.005 EU/mL, 10 × 88 tips
    Price is loading...
    Sku LONBE25-414
    Manufact. SkuBE25-414
    Packaging Unit5 plugs
  2. Tips LAL reag grade 2-200µl 10X96 tips
    LAL Reagent GradeTMPipette Tips, 2–200 µL, <0.005 EU/mL, 10 × 96 tips
    Price is loading...
    Sku LONBE25-413
    Manufact. SkuBE25-413
    Packaging Unit160 µl
  3. 15 ml Sample Cont. 50 Tubes,Endo tested
    Polystyrene Sample Container, 15 mL tubes
    Price is loading...
    Sku LONBE2099
    Manufact. SkuBE2099
    Packaging Unit50 pieces
  4. 50 ml sample cont. 50pieces, Endo tested
    Polypropylene Sample Container, 50 mL tubes
    Price is loading...
    Sku LONBE2098
    Manufact. SkuBE2098
    Packaging Unit50 pieces
  5. Pyrogent-5000 Reconstitution Buffer, for T50-600U
    PYROGENT-5000 Bulk Kinetic Turbidimetric Reconstitution Buffer
    Price is loading...
    Sku LONB50-600U
    Manufact. SkuB50-600U
    Packaging Unit1 Stück
  6. Pyrogent-5000 Reconstitution Buffer, for T50-600L
    PYROGENT-5000 Bulk Kinetic Turbidimetric Reconstitution Buffer
    Price is loading...
    Sku LONB50-600L
    Manufact. SkuB50-600L
    Packaging Unit1 Stück
  7. Pyrogent-5000 Reconstitution Buffer, 100 vials 5,2ml (for T50-300U)
    PYROGENT-5000 Bulk Kinetic Turbidimetric Reconstitution Buffer
    Price is loading...
    Sku LONB50-300U
    Manufact. SkuB50-300U
    Packaging Unit1 Stück
  8. PYROGENT-5000 RECONSTITUTION BUFFER
    PYROGENT-5000 Bulk Kinetic Turbidimetric Reconstitution Buffer
    Price is loading...
    Sku LONB50-300L
    Manufact. SkuB50-300L
    Packaging Unit25 vials
  9. Pyrogent-5000 Reconstitution Buffer,1 vial 5,2ml
    Pyrogent 5000 - reconstitution buffer - 1 vials of 5.2 ml
    Price is loading...
    Sku LONB50-300
    Manufact. SkuB50-300
    Packaging Unit1 vial
  10. Combitips 10 ml (1 EA = 100 tips)
    Individually wrapped, Eppendorf® Combitips, 10 mL, 100 tips. Ideal in endotoxin testing applications.
    Price is loading...
    Sku LON89677
    Manufact. Sku89677
    Packaging Unit60 ml