Mouse anti Human CD15-NA FITC

Mouse anti Human CD15-NA FITC, IgG3, Clone: MCS-1
SKU
EXAX1496M
Packaging Unit
50 Tests
Manufacturer
Exalpha Biologicals Inc

Availability: loading...
Price is loading...
Clone: MCS-1

Label: FITC

Background: CD15-FITC is a monoclonal antibody (MAb) labelled with fluorescein isothiocyanate (FITC) designed for use as a direct immunofluorescence reagent in the identification and enumeration of cells which express the CD15 antigen by flow cytometry. The CD15 MAb is applied for the initial evaluation of acute myeloid leukemia (AML) and myelodysplastic syndromes (MDS) together with a panel of other antibodies. Interpretation of results must be made within the context of the patientÕs clinical history and other diagnostic tests by a certified professional.

Purification Method: Affinity Chromatography

Concentration: Titered for flow cytometry

References: 1. Ball ED. M5. CD15 cluster workshop report. In: Schlossman SF, Boumsell L, Gilks W, Harlan JM, Kishimoto T, Morimoto C, Ritz J, et al. editors. Leucocyte typing V. White cell differentiation antigens. Proceedings of Fifth International Workshop and conference held in Boston, USA 3-7 november, 1993. Volume One. Oxford University Press (1995).2. Bahia DMM, Yamamoto M, Chauffaille MLF, Kimura EYS, Bordin JO, et al. Aberrant phenotypes in acute myeloid leukemia: a high frequency and clinical significance. Haematologica.86: 801-806 (2001)3. van Gongen JJM, Adriaansen HJ. Immunobiology of leukemia. In Henderson ES, Lister TA, Greaves MF editors. Leukemia. WB Saunders Company (1996)4. Menéndez P, et al. Comparison between a lyse-and-then-wash method and a lyse-non-wash technique for the enumeration of CD34+ hematopoietic progenitor cells. Cytometry (Comm. Clin. Cytometry) 34: 264-271 (1998)5. GratamaJW, Menéndez P, Kraan J, Orfao A. Loss of CD34+ hematopoietic progenitor cells due to washing can be reduced by the use of fixative-free erytrocyte lysing reagents. J Immunol. Methods 239: 13-23 (2000)6. Protection of Laboratory Workers from occupationally acquired infections. Second edition; approved guideline (2001). Villanova PA: National Committee for Clinical Laboratory Standards; Document M29-A2.7. Procedures for the collection of diagnostic blood specimens by venipuncture- approved standard; Fifth edition (2003). Wayne PA: National Committee for Clinical Laboratory Standards; Document H3-A5.8. Clinical applications of flow cytometry: Quality assurance and immunophenotyping of lymphocytes; approved guideline (1998). Wayne PA: National Committee for Clinical Laboratory Standards; Document H42-A.9. Braylan RC, Orfao A, Borowitz MJ, Davis BH. Optimal number of reagents required to evaluate hematolymphoid neoplasias: results of an international consensus meeting. Cytometry 46: 23-7 (2001)10. Jennings CD, Foon KA. Recent advances in flow cytometry: application to the diagnosis of hematologic malignancy. Blood 90(8): 2863-2892 (1997)11. Orfao A, Ortuño F, de Santiago M, López A, San Miguel J. Immunophenotyping of acute leucemias and myelodysplastic syndromes. Cytometry Part A 58A: 62-71 (2004)12. Reichert et al. Lymphocyte subset reference ranges in adult Caucasians. Clin Immunol Immunopathol 60:190-208 (1991)

Caution: This product is intended FOR RESEARCH USE ONLY, and FOR TESTS IN VITRO, not for use in diagnostic or therapeutic procedures involving humans or animals.
More Information
SKU EXAX1496M
Manufacturer Exalpha Biologicals Inc
Manufacturer SKU X1496M
Package Unit 50 Tests
Quantity Unit PAK
Reactivity Human
Clonality Monoclonal
Application Flow Cytometry
Isotype IgG3
Host Mouse
Conjugate Unconjugated
Product information (PDF) Download
MSDS (PDF) Download