Usage: This ELISA kit applies to the in vitro quantitative determination of Human VEGF-A concentrations in serum, plasma.
Tested Sample Types: serum, plasma
Assay Time: 2.5h
Sensitivity: 0.03 ng/mL
Detection Range: 0.04-10 ng/mL
UNIProt ID: P15692
Test Principle: This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human VEGF-A. Samples (or Standards) are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human VEGF-A and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human VEGF-A, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ± 2 nm. The OD value is proportional to the concentration of Human VEGF-A. You can calculate the concentration of Human VEGF-A in the samples by comparing the OD of the samples to the standard curve.
Cross reactivity: This kit recognizes Human VEGF-A in samples.No significant cross-reactivity or interference between Human VEGF-A and analogues was observed